Back to Profile
Blood sample "COL-017-01" Details
Overview
Collection ID
COL-017-01
Collection date
07 Sep 2025
Collection type
Capillary
Collection place
Home
Collector
Nurse
Device type
TAP Micro Select
Part
A
Analytes
7
Analyte results
| Analyte | Result | Unit | Reference range |
|---|---|---|---|
| Vitamin D | 27 | ng/mL | Below reference range |
| Cystatin C | 1.56 | mg/L | Above reference range |
| HDL | 66.45 | mg/dL | Within normal range |
| LDL | 192.3 | mg/dL | Above reference range |
| Albumin | 3.1 | g/dL | Below reference range |
| Creatinine | 0.82 | mg/dL | Within normal range |
| AST | 9.91 | U/L | Below reference range |
Collection details
Collection
| Sample collection date | 07 Sep 2025 |
| Date & time of sample collection (clinic or home) | 2025-09-07 03:45 |
| Collection time | 23:00 |
| Place of collection (Clinic, Home) | Home |
| Who performed collection | Nurse |
| Complete? | Yes |
| Sample code | S-017-01-1545 |
| Visit | Other |
| Kit code | KIT-63672 |
| Number of attempts to get full sample | 1 |
| Reason(s) for unsuccessful attempt(s) | None |
| Self-collection by | Participant |
Venous blood
| Was venous blood collected? | No |
| Venous Blood Collected | No |
| Unique identifier for venous blood sample | Not applicable |
| Volume Venous (Tube Vacuette yellow) | — |
| Volume Venous (Tube Vacuette purple) | — |
Capillary / microsampling
| Was capillarity blood collected? | Yes |
| Microsampling device | TAP Micro Select |
| PCmS TAP Micro Select Collected | Yes |
| PCmS Greiner Bio-OneMiniCollect EDTA Collected | No |
| PCmS TAP Micro Volume | 182 µL |
| PCmS Greiner Bio-OneMiniCollect EDTA Volume | — |
Microsampling device codes
| Code linked to microsampling device used (TAP Micro Select) | DC-TAPM-2450 |
| Code linked to microsampling device used (Greiner MiniCollect EDTA) | — |
| Code linked to microsampling device used (Tasso+) | — |
| Code linked to microsampling device used (Tasso mini) | — |
| Code linked to microsampling device used (Capitainer B) | — |
| Code linked to microsampling device used (Whatman 903 PSC) | — |
| Code linked to microsampling device used (Hemaspot SE) | — |
Kit / tubes request codes
| Kit / tubes request code (TAP Micro Select) | KT-45146 |
| Kit / tubes request code (Greiner MiniCollect EDTA) | — |
| Kit / tubes request code (Tasso+) | — |
| Kit / tubes request code (Tasso mini) | — |
| Kit / tubes request code (Capitainer B) | — |
| Kit / tubes request code (Whatman 903 PSC) | — |
| Kit / tubes request code (Hemaspot SE) | — |
Home collection & delivery
| Home collection date | 07 Sep 2025 |
| Home collection time | 06:33 |
| Lab delivery date | 08 Sep 2025 |
| Lab delivery time | 20:38 |
| Time to analysis (h) | 40 |
| Samples received | Yes |
Sample quality
| Preservation status | Insufficient volume |
| Other quality measures | Visual inspection acceptable |
| Hemolysis index | 6.9 |
| Ictericia index | 14.7 |
| Lipemia index | 0.6 |
| Suitable for analysis | Yes |
| Matrix | Capillar |
Measurement
| Measurement method | Other |
| Method (specify) | — |
| Equipment / device | Sysmex XN-1000 |
| LOQ flag | No (quantifiable) |
Lab comments
| Comment | Sample processed without incident. |